{"action":"create","ckan_id":null,"date_created":"Sat, 28 Feb 2026 20:42:46 GMT","date_finished":null,"harvest_job_id":"6ffa3b4c-5787-478c-b13f-c34182db1fa4","harvest_source_id":"31f41541-38a0-400b-b240-10ebcb0acd9a","id":"3957ede2-e2d4-4750-8ce2-71b3d572a663","identifier":"https://dggs.alaska.gov/webpubs/metadata/RDF2013-2.xml","parent_identifier":null,"source_hash":"be4abae9851bb6528987c733f8fcd63b1ffde0939a02eafb9cf34cbf9705a33b","source_raw":"<?xml version=\"1.0\" encoding=\"UTF-8\"?>\n<metadata>\n<idinfo>\n<citation>\n<citeinfo>\n<origin>Stevens, D.S.P.</origin>\n<origin>Werdon, M.B.</origin>\n<origin>Wright, T.C.</origin>\n<pubdate>2013</pubdate>\n<title>Geochemical trace-element and rare-earth element data from rock samples collected in 2012 on Annette Island, southeast Alaska</title>\n<geoform>document, digital data download</geoform>\n<serinfo>\n<sername>Raw Data File</sername>\n<issue>RDF 2013-2</issue>\n</serinfo>\n<pubinfo>\n<pubplace>Fairbanks, AK, USA</pubplace>\n<publish>Alaska Division of Geological &amp; Geophysical Surveys</publish>\n</pubinfo>\n<othercit>2 p.</othercit>\n<onlink>http://dx.doi.org/10.14509/24975</onlink>\n</citeinfo>\n</citation>\n<descript>\n<abstract>Personnel from the Alaska Division of Geological &amp; Geophysical Surveys (DGGS) conducted a reconnaissance rock sampling project from April 30 to May 4, 2012, to obtain modern, quantitative geochemical analyses to characterize select mafic-ultramafic rocks and one chalcopyrite-bearing quartz vein sample from Yellow Hill on Annette Island, in the Ketchikan Quadrangle, southeastern Alaska. Highlights of this sampling project include mafic-ultramafic rock samples with up to 0.079 ppm platinum (Pt) and 0.123 ppm palladium (Pd), and a quartz vein with 2.83 percent copper (Cu) and 0.155 ppm gold (Au).</abstract>\n<purpose>This work was conducted as a component of the State of Alaska's Strategic and Critical Minerals Assessment Project, which was initiated to evaluate Alaska's potential for critical mineral resources.</purpose>\n<supplinf>In addition to the data tables, this distribution package includes ALS Chemex-provided PDFs that describe their sample preparation and geochemical analysis procedures. The DGGS metadata standard extends the FGDC standard to include elements that are required to facilitate our internal data management. These elements, referred to as \"layers,\" group and describe files that have intrinsic logical or topological relationships. This dataset is described as a single layer. Attribute information for the layer is included in this metadata file under the \"Entity_and_Attribute_Information\" section. The layer is titled:     &gt;rock-trace-element-ree:    This data distribution package consists of two CSV files which provide sample locations and descriptions, geochemical data, analytical methods, and instrumentation detection limits for trace element and rare earth element analysis of rock samples.</supplinf>\n</descript>\n<timeperd>\n<timeinfo>\n<rngdates>\n<begdate>2012</begdate>\n<enddate>2013</enddate>\n</rngdates>\n</timeinfo>\n<current>ground condition</current>\n</timeperd>\n<status>\n<progress>complete</progress>\n<update>none planned</update>\n</status>\n<spdom>\n<bounding>\n<westbc>-131.5801</westbc>\n<eastbc>-131.5517</eastbc>\n<northbc>55.1778</northbc>\n<southbc>55.0864</southbc>\n</bounding>\n</spdom>\n<keywords>\n<theme>\n<themekt>ISO 19115 Topic Category</themekt>\n<themekey>geoscientificInformation</themekey>\n</theme>\n<theme>\n<themekt>Alaska Division of Geological &amp; Geophysical Surveys</themekt>\n<themekey>Geochemical Data</themekey>\n<themekey>Geochemical Surveys</themekey>\n<themekey>Geochemistry</themekey>\n<themekey>Rare Earth Elements</themekey>\n<themekey>Trace Geochemical</themekey>\n<themekey>Trace Metals</themekey>\n<themekey>Strategic Minerals</themekey>\n</theme>\n<place>\n<placekt>Alaska Division of Geological &amp; Geophysical Surveys</placekt>\n<placekey>Ketchikan Quadrangle</placekey>\n</place>\n</keywords>\n<accconst>This report, map, and/or dataset is available directly from the State of Alaska, Department of Natural Resources, Division of Geological &amp; Geophysical Surveys (see contact information below).</accconst>\n<useconst>Any hard copies or published datasets utilizing these datasets shall clearly indicate their source. If the user has modified the data in any way, the user is obligated to describe the types of modifications the user has made. The user specifically agrees not to misrepresent these datasets, nor to imply that changes made by the user were approved by the State of Alaska, Department of Natural Resources, Division of Geological &amp;amp; Geophysical Surveys. The State of Alaska makes no express or implied warranties (including warranties for merchantability and fitness) with respect to the character, functions, or capabilities of the electronic data or products or their appropriateness for any user's purposes. In no event will the State of Alaska be liable for any incidental, indirect, special, consequential, or other damages suffered by the user or any other person or entity whether from the use of the electronic services or products or any failure thereof or otherwise. In no event will the State of Alaska's liability to the Requestor or anyone else exceed the fee paid for the electronic service or product.</useconst>\n<ptcontac>\n<cntinfo>\n<cntorgp>\n<cntorg>Alaska Division of Geological &amp; Geophysical Surveys</cntorg>\n<cntper>James Weakland</cntper>\n</cntorgp>\n<cntpos>GIS Analyst</cntpos>\n<cntaddr>\n<addrtype>mailing and physical</addrtype>\n<address>3354 College Road</address>\n<city>Fairbanks</city>\n<state>AK</state>\n<postal>99709-3707</postal>\n<country>USA</country>\n</cntaddr>\n<cntvoice>(907)451-5029</cntvoice>\n<cntvoice>(907)451-5020</cntvoice>\n<cntemail>dggsgis@alaska.gov</cntemail>\n<hours>8 am to 4:30 pm, Monday through Friday, except State holidays</hours>\n</cntinfo>\n</ptcontac>\n<datacred>The DGGS would like to thank the Metlakatla Indian Community for permission to collect samples and publish the associated geochemical assays. Analyses were paid for by the State of Alaska's Strategic and Critical Minerals Assessment CIP, which is funded by the Alaska State Legislature and managed by the State of Alaska, Department of Natural Resources, Division of Geological &amp; Geophysical Surveys. Funding for DGGS travel and field time was provided by the MapTEACH program, funded by the U.S. Department of Education, Alaska Native Education Program (Award Number S356A090040).</datacred>\n<crossref>\n<citeinfo>\n<origin>Werdon, M.B.</origin>\n<origin>Gallagher, P.E.</origin>\n<origin>Blessington, M.J.</origin>\n<pubdate>2012</pubdate>\n<title>Geochemical, major-oxide, minor-oxide, trace-element, and rare-earth-element data from rock, stream sediment, and pan-concentrate samples collected in 2011 in the William Henry Bay area, Juneau C-4 and D-4 quadrangles, Southeast Alaska</title>\n<geoform>document, digital data download</geoform>\n<serinfo>\n<sername>Raw Data File</sername>\n<issue>RDF 2012-2</issue>\n</serinfo>\n<pubinfo>\n<pubplace>Fairbanks, AK, USA</pubplace>\n<publish>Alaska Division of Geological &amp; Geophysical Surveys</publish>\n</pubinfo>\n<othercit>2 p</othercit>\n<onlink>http://dx.doi.org/10.14509/23843</onlink>\n</citeinfo>\n</crossref>\n</idinfo>\n<dataqual>\n<attracc>\n<attraccr>Instrumentation detection limits were provided by ALS Chemex. In addition to the internal quality-control program at ALS Chemex, DGGS monitored analysis quality by inserting ore-geochemical-pulp standards with known compositions into the sample roster for every sample batch.</attraccr>\n</attracc>\n<logic>Not applicable</logic>\n<complete>All samples were analyzed for ore-related trace elements and the full suite of rare-earth elements.</complete>\n<posacc>\n<horizpa>\n<horizpar>Location coordinates were obtained using Garmin eTrex Legend H and Garmin GPSmap 76S handheld GPS units with a typical error of 7 m or less.</horizpar>\n</horizpa>\n</posacc>\n<lineage>\n<procstep>\n<procdesc>Sample collection - DGGS staff and student field assistants collected select ultramafic rock samples and a chalcopyrite-bearing quartz vein sample for geochemical analysis. Location coordinates were obtained using Garmin eTrex Legend H and Garmin GPSmap 76S handheld GPS units with a typical error of 7 m or less.</procdesc>\n<procdate>2012</procdate>\n</procstep>\n<procstep>\n<procdesc>Sample preparation - Samples were submitted to ALS Chemex, where the rock samples were logged in the tracking system, weighed, dried, and finely crushed to better than 70 percent passing through a 2 mm (Tyler 9 mesh, U.S. Std. No. 10) screen. A split of up to 250 g was taken and pulverized to better than 85 percent passing through a 75 micron (Tyler 200 mesh, U.S. Std. No. 200) screen.</procdesc>\n<procdate>2012</procdate>\n</procstep>\n<procstep>\n<procdesc>Analytical methods - All samples were analyzed for ore-related trace elements and the full suite of rare-earth elements. In addition to the internal quality-control program at ALS Chemex, DGGS monitored analysis quality by inserting ore-geochemical-pulp standards with known compositions into the sample roster for every sample batch. Trace-element compositions were determined using inductively coupled plasma, atomic emission spectroscopy (ICP-AES) following a four-acid digestion process. Rare-earth- and additional trace-element compositions were determined using inductively coupled plasma, mass spectroscopy (ICP-MS). ICP-MS samples were dissolved in acid following lithium borate fusion. Platinum (Pt), palladium (Pd), and gold (Au) values were obtained from a 30-gram sample using inductively coupled plasma-atomic emission spectroscopy (ICP-AES) following fire assay. The sample from the Erbelding prospect was outside the range for copper for this method, and was re-analyzed using gravimetry (ICP-AES). Detection limits for each of the reported elemental values obtained by the various methods are provided in the digital data distribution files.</procdesc>\n<procdate>2012</procdate>\n</procstep>\n</lineage>\n</dataqual>\n<spdoinfo>\n<direct>point</direct>\n</spdoinfo>\n<spref>\n<horizsys>\n<geodetic>\n<horizdn>World Geodetic System of 1984</horizdn>\n<ellips>World Geodetic System of 1984</ellips>\n<semiaxis>6378137</semiaxis>\n<denflat>298.257223563</denflat>\n</geodetic>\n</horizsys>\n</spref>\n<eainfo>\n<detailed>\n<enttyp>\n<enttypl>rdf2013-2-rock-trace-element-ree.csv, rdf2013-2-rock-trace-element-ree-limits.csv</enttypl>\n<enttypd>This data distribution package consists of two CSV files which provide sample locations and descriptions, geochemical data, analytical methods, and instrumentation detection limits for trace element and rare earth element analysis of rock samples. The primary table, rdf2013-2-rock-trace-element-ree.csv presents the analytical results and sample locations. A secondary table, rdf2013-2-rock-trace-element-ree-limits.csv provides detailed information about the methods and detection limits of the instrumentation used to analyze this data. Attribute information for the primary table is provided below.</enttypd>\n<enttypds>Alaska Division of Geological &amp; Geophysical Surveys</enttypds>\n<ealname>rock-trace-element-ree</ealname>\n</enttyp>\n<attr>\n<attrlabl>Sample</attrlabl>\n<attrdef>Label assigned to identify the sample</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys</attrdefs>\n<attrdomv>\n<udom>Sample identifiers were assigned by students of Mr. Rob Erbelding and Mr. Jason Pipkin.</udom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Description</attrlabl>\n<attrdef>Description of the sample</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys</attrdefs>\n<attrdomv>\n<udom>Samples were derived from outcrops of mafic-ultramafic rocks and from one chalcopyrite-bearing quartz vein.</udom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Latitude</attrlabl>\n<attrdef>Latitude, WGS84</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>55.0864</rdommin>\n<rdommax>55.1778</rdommax>\n<attrunit>decimal degrees</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Longitude</attrlabl>\n<attrdef>Longitude, WGS84</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>-131.5801</rdommin>\n<rdommax>-131.5517</rdommax>\n<attrunit>decimal degrees</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Weight_kg</attrlabl>\n<attrdef>Sample weight in kilograms</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>0.14</rdommin>\n<rdommax>1.67</rdommax>\n<attrunit>kilograms</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ba_ppm_1</attrlabl>\n<attrdef>Barium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.5 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>0.5</rdommin>\n<rdommax>68.1</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ce_ppm</attrlabl>\n<attrdef>Cerium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.5 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.5</rdommin>\n<rdommax>11.4</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Cr_ppm_1</attrlabl>\n<attrdef>Chromium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 10 ppm; Upper detection limit = 10 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-2</edomv>\n<edomvd>Above detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>30</rdommin>\n<rdommax>6280</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Cs_ppm</attrlabl>\n<attrdef>Cesium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.01 ppm; Upper detection limit = 0.01 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.14</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Dy_ppm</attrlabl>\n<attrdef>Dysprosium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.05 ppm; Upper detection limit = 0.05 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.05</rdommin>\n<rdommax>1.14</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Er_ppm</attrlabl>\n<attrdef>Erbium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.03 ppm; Upper detection limit = 0.03 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.03</rdommin>\n<rdommax>0.67</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Eu_ppm</attrlabl>\n<attrdef>Europium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.03 ppm; Upper detection limit = 0.03 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.03</rdommin>\n<rdommax>0.53</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ga_ppm_1</attrlabl>\n<attrdef>Gallium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.1 ppm; Upper detection limit = 0.1 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>0.4</rdommin>\n<rdommax>4.4</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Gd_ppm</attrlabl>\n<attrdef>Gadolinium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.05 ppm; Upper detection limit = 0.05 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.05</rdommin>\n<rdommax>1.58</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Hf_ppm</attrlabl>\n<attrdef>Hafnium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.2 ppm; Upper detection limit = 0.2 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.2</rdommin>\n<rdommax>1.2</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ho_ppm</attrlabl>\n<attrdef>Holmium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.01 ppm; Upper detection limit = 0.01 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.21</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>La_ppm_1</attrlabl>\n<attrdef>Lanthanum values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.5 ppm; Upper detection limit = 0.5 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.6</rdommin>\n<rdommax>2.9</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Lu_ppm</attrlabl>\n<attrdef>Lutetium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.01 ppm; Upper detection limit = 0.01 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.08</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Nb_ppm</attrlabl>\n<attrdef>Niobium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.2 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.2</rdommin>\n<rdommax>5.1</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Nd_ppm</attrlabl>\n<attrdef>Neodymium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.1</rdommin>\n<rdommax>6</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Pr_ppm</attrlabl>\n<attrdef>Praseodymium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.03 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.03</rdommin>\n<rdommax>1.38</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Rb_ppm</attrlabl>\n<attrdef>Rubidium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.2 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.2</rdommin>\n<rdommax>9.2</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Sm_ppm</attrlabl>\n<attrdef>Samarium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.03 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.03</rdommin>\n<rdommax>1.31</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Sn_ppm</attrlabl>\n<attrdef>Tin values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>1</rdommin>\n<rdommax>1</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Sr_ppm_1</attrlabl>\n<attrdef>Strontium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>1.4</rdommin>\n<rdommax>55.6</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ta_ppm</attrlabl>\n<attrdef>Tantalum values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.3</rdommin>\n<rdommax>0.3</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Tb_ppm</attrlabl>\n<attrdef>Terbium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.01 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.2</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Th_ppm_1</attrlabl>\n<attrdef>Thorium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.05 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.05</rdommin>\n<rdommax>0.4</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Tl_ppm_1</attrlabl>\n<attrdef>Thallium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.5 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Tm_ppm</attrlabl>\n<attrdef>Thulium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.01 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.09</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>U_ppm_1</attrlabl>\n<attrdef>Uranium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.05 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.05</rdommin>\n<rdommax>0.45</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>V_ppm_1</attrlabl>\n<attrdef>Vanadium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 5 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>35</rdommin>\n<rdommax>103</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>W_ppm_1</attrlabl>\n<attrdef>Tungsten values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>1</rdommin>\n<rdommax>1</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Y_ppm</attrlabl>\n<attrdef>Yttrium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.5 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.8</rdommin>\n<rdommax>6.7</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Yb_ppm</attrlabl>\n<attrdef>Ytterbium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 0.03 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.03</rdommin>\n<rdommax>0.54</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Zr_ppm</attrlabl>\n<attrdef>Zirconium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), Lithium metaborate fusion - HNO3-HCl dissolution ; Lower detection limit = 2 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>20</rdommin>\n<rdommax>50</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ag_ppm</attrlabl>\n<attrdef>Silver values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.5 ppm; Upper detection limit = 100 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.5</rdommin>\n<rdommax>0.8</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Al_pct</attrlabl>\n<attrdef>Aluminum values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 50 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>0.03</rdommin>\n<rdommax>1.52</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>As_ppm</attrlabl>\n<attrdef>Arsenic values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 5 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>5</rdommin>\n<rdommax>5</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ba_ppm_2</attrlabl>\n<attrdef>Barium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 10 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>10</rdommin>\n<rdommax>80</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Be_ppm</attrlabl>\n<attrdef>Beryllium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.5 ppm; Upper detection limit = 1000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.5</rdommin>\n<rdommax>0.5</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Bi_ppm</attrlabl>\n<attrdef>Bismuth values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 2 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>2</rdommin>\n<rdommax>15</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ca_pct</attrlabl>\n<attrdef>Calcium values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 50 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>0.03</rdommin>\n<rdommax>10.9</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Cd_ppm</attrlabl>\n<attrdef>Cadmium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.5 ppm; Upper detection limit = 500 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Co_ppm</attrlabl>\n<attrdef>Cobalt values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>7</rdommin>\n<rdommax>147</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Cr_ppm_2</attrlabl>\n<attrdef>Chromium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-2</edomv>\n<edomvd>Above detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>33</rdommin>\n<rdommax>3200</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Cu_ppm</attrlabl>\n<attrdef>Copper values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-2</edomv>\n<edomvd>Above detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>1</rdommin>\n<rdommax>35</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Fe_pct</attrlabl>\n<attrdef>Iron values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 50 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>4.17</rdommin>\n<rdommax>11.25</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ga_ppm_2</attrlabl>\n<attrdef>Gallium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 10 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>10</rdommin>\n<rdommax>10</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>K_pct</attrlabl>\n<attrdef>Potassium values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 10 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.63</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>La_ppm_2</attrlabl>\n<attrdef>Lanthanum values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 10 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Mg_pct</attrlabl>\n<attrdef>Magnesium values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 50 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>0.31</rdommin>\n<rdommax>26.2</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Mn_ppm</attrlabl>\n<attrdef>Manganese values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 5 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>217</rdommin>\n<rdommax>1470</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Mo_ppm</attrlabl>\n<attrdef>Molybdenum values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>1</rdommin>\n<rdommax>12</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Na_pct</attrlabl>\n<attrdef>Sodium values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 10 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.21</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ni_ppm</attrlabl>\n<attrdef>Nickel values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>9</rdommin>\n<rdommax>1890</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>P_ppm</attrlabl>\n<attrdef>Phosphorus values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 10 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>10</rdommin>\n<rdommax>820</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Pb_ppm</attrlabl>\n<attrdef>Lead values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 2 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>5</rdommin>\n<rdommax>5</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>S_pct</attrlabl>\n<attrdef>Sulfur values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 10 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>2.47</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Sb_ppm</attrlabl>\n<attrdef>Antimony values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 5 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Sc_ppm</attrlabl>\n<attrdef>Scandium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>3</rdommin>\n<rdommax>85</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Sr_ppm_2</attrlabl>\n<attrdef>Strontium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>1</rdommin>\n<rdommax>55</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Th_ppm_2</attrlabl>\n<attrdef>Thorium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 20 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Ti_pct</attrlabl>\n<attrdef>Titanium values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 0.01 pct; Upper detection limit = 10 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.01</rdommin>\n<rdommax>0.18</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Tl_ppm_2</attrlabl>\n<attrdef>Thallium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 10 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>10</rdommin>\n<rdommax>20</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>U_ppm_2</attrlabl>\n<attrdef>Uranium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 10 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>20</rdommin>\n<rdommax>20</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>V_ppm_2</attrlabl>\n<attrdef>Vanadium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 1 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>3</rdommin>\n<rdommax>110</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>W_ppm_2</attrlabl>\n<attrdef>Tungsten values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 10 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Zn_ppm</attrlabl>\n<attrdef>Zinc values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HF-HNO3-HClO4-HCl; Lower detection limit = 2 ppm; Upper detection limit = 10000 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>17</rdommin>\n<rdommax>114</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Cu_pct</attrlabl>\n<attrdef>Copper values measured in percent (pct); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), HNO3-HClO4-HF+HCl; Lower detection limit = 0.001 pct; Upper detection limit = 40 pct; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>null or blank</edomv>\n<edomvd>Chemical species not requested or not analyzed</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>2.83</rdommin>\n<rdommax>2.83</rdommax>\n<attrunit>percent</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Au_ppm</attrlabl>\n<attrdef>Gold values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), Fire assay - aqua regia; Lower detection limit = 0.01 ppm; Upper detection limit = 10 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<rdom>\n<rdommin>0.002</rdommin>\n<rdommax>0.155</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Pt_ppm</attrlabl>\n<attrdef>Platinum values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), Fire assay - aqua regia; Lower detection limit = 0.005 ppm; Upper detection limit = 10 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.005</rdommin>\n<rdommax>0.079</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n<attr>\n<attrlabl>Pd_ppm</attrlabl>\n<attrdef>Palladium values measured in parts per million (ppm); Method and digestion: Inductively Coupled Plasma - Atomic Emission Spectroscopy (ICP-AES), Fire assay - aqua regia; Lower detection limit = 0.001 ppm; Upper detection limit = 10 ppm; Detection limits indicate the minimum and maximum concentrations that can be accurately determined.</attrdef>\n<attrdefs>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex.</attrdefs>\n<attrdomv>\n<edom>\n<edomv>-1</edomv>\n<edomvd>Below detection limit.</edomvd>\n<edomvds>Alaska Division of Geological &amp; Geophysical Surveys and ALS Chemex</edomvds>\n</edom>\n</attrdomv>\n<attrdomv>\n<rdom>\n<rdommin>0.001</rdommin>\n<rdommax>0.123</rdommax>\n<attrunit>parts per million</attrunit>\n</rdom>\n</attrdomv>\n</attr>\n</detailed>\n</eainfo>\n<distinfo>\n<distrib>\n<cntinfo>\n<cntorgp>\n<cntorg>Alaska Division of Geological &amp; Geophysical Surveys</cntorg>\n</cntorgp>\n<cntaddr>\n<addrtype>mailing and physical</addrtype>\n<address>3354 College Road</address>\n<city>Fairbanks</city>\n<state>AK</state>\n<postal>99709-3707</postal>\n<country>USA</country>\n</cntaddr>\n<cntvoice>(907)451-5020</cntvoice>\n<cntfax>(907)451-5050</cntfax>\n<cntemail>dggspubs@alaska.gov</cntemail>\n<hours>8 am to 4:30 pm, Monday through Friday, except State holidays</hours>\n<cntinst>Please view our website (http://www.dggs.alaska.gov) for the latest information on available data. Please contact us using the e-mail address provided above when possible.</cntinst>\n</cntinfo>\n</distrib>\n<resdesc>RDF 2013-2</resdesc>\n<distliab>The State of Alaska makes no expressed or implied warranties (including warranties for merchantability and fitness) with respect to the character, functions, or capabilities of the electronic data or products or their appropriateness for any user's purposes. In no event will the State of Alaska be liable for any incidental, indirect, special, consequential, or other damages suffered by the user or any other person or entity whether from the use of the electronic services or products or any failure thereof or otherwise. In no event will the State of Alaska's liability to the Requestor or anyone else exceed the fee paid for the electronic service or product.</distliab>\n<stdorder>\n<nondig>DGGS publications are available as free online downloads or you may purchase paper hard-copies or digital files on CD/DVD or other digital storage media by mail, phone, fax, or email from the DGGS Fairbanks office. To purchase this or other printed reports and maps, contact DGGS by phone (907-451-5020), e-mail (dggspubs@alaska.gov), or fax (907-451-5050). Payment accepted: Cash, check, money order, VISA, or MasterCard. Turnaround time is 1-2 weeks unless special arrangements are made and an express fee is paid. Shipping charge will be the actual cost of postage and will be added to the total amount due. Contact us for the exact shipping amount.</nondig>\n<fees>Contact DGGS for current pricing</fees>\n</stdorder>\n<stdorder>\n<digform>\n<digtinfo>\n<formname>ASCII tabular files</formname>\n</digtinfo>\n<digtopt>\n<onlinopt>\n<computer>\n<networka>\n<networkr>http://dx.doi.org/10.14509/24975</networkr>\n</networka>\n</computer>\n</onlinopt>\n</digtopt>\n</digform>\n<fees>Free download</fees>\n</stdorder>\n</distinfo>\n<metainfo>\n<metd>20130906</metd>\n<metc>\n<cntinfo>\n<cntperp>\n<cntper>Metadata manager</cntper>\n</cntperp>\n<cntaddr>\n<addrtype>mailing and physical</addrtype>\n<address>3354 College Road</address>\n<city>Fairbanks</city>\n<state>AK</state>\n<postal>99709-3707</postal>\n<country>USA</country>\n</cntaddr>\n<cntvoice>(907)451-5020</cntvoice>\n</cntinfo>\n</metc>\n<metstdn>FGDC Content Standard for Digital Geospatial Metadata</metstdn>\n<metstdv>FGDC-STD-001-1998</metstdv>\n<metuc>If the user has modified the data in any way they are obligated to describe the types of modifications they have performed in the supporting metadata file. User specifically agrees not to imply that changes they made were approved by the Alaska Department of Natural Resources or Division of Geological &amp; Geophysical Surveys.</metuc>\n<metextns>\n<onlink>http://www.dggs.alaska.gov/metadata/dggs.ext</onlink>\n<metprof>dggs metadata extensions</metprof>\n</metextns>\n</metainfo>\n</metadata>\n","source_transform":null,"status":"error"}
